Model and documentation reference
Selected model: standard ETC ColorSource 20, CS20, distinct from CS20AV, CS40 and CS40AV. References are manual 3.4.0 Rev A released April 2026 and data sheet Rev H dated August 2026. Record installed model, software and library before applying controls. AV networking, audio, HDMI and Amigo connections are not attributed to the standard console.
ETC ColorSource Consoles · Rev H 2026-08 · CS20 standard section
Event application
For presentation, reception and closing, define the required scenes and operator. Request fixture models and modes even from an initial provisional list; a multiparameter personality and a simple dimmer need different preparation. Fader count does not replace addressing, DMX footprint and attribute checks. Agree on the operator file and preservation of the original during preparation.
Keep five facts separate
| Information | Standard CS20 reference | Event record |
|---|---|---|
| Surface | 20 channel/playback faders in the data sheet | Function used in the intended operation |
| Control channel | Can represent a multiparameter fixture | Exact model, mode and personality |
| Physical output | One DMX/RDM port and one USB | Identified DMX line and copy medium |
| Master | Distinct Cues and Playbacks functions | Observed assignment and level, not assumed position |
| File | Internal Save As and USB Export are separate tasks | Show name and external copy to verify |
ColorSource manual · 3.4.0 Rev A 2026-04 · selected pages · existing original
Compare the same fixture through two control paths
Prepare a row with fixture, mode, address, control channel and look. The manual separates Add Dimmer for simple intensity from Add Device for multiparameter fixtures; an incorrect color response may need a matching-profile check before recording a compensating cue. Compare manual control and recorded content on the same patch. Preserve observed selection and manual contributions because they can affect output alongside playback.
ColorSource manual · 3.4.0 Rev A 2026-04 · selected pages · existing original
Masters and color need specific observation
Cues and Playbacks have their own masters with configurable assignments. Read actual function and level before proposing a change; do not raise every control to recover a look. The manual describes HTP for playback intensity and color, allowing two color contributions to combine. This is not a rule for all parameters. It also states that position may continue at zero playback-master level: a dark image establishes no absence of data or movement.
ColorSource manual · 3.4.0 Rev A 2026-04 · selected pages · existing original
Prepare a comparison without altering the live show
- Record standard CS20, observed software/library, operating mode and original file. Preserve master-assignment evidence before proposing changes.
- Prepare fixture map with personality, mode, address and DMX footprint. Define a recognizable off-program sample using a known fixture.
- Separate intended manual, playback and cue contributions. Agree on comparison of individual paths and planned combinations, observing intensity, color and position separately.
- Record Cues/Playbacks labels and levels with expected and observed results. Do not unassign a master as diagnosis: support references disagree on the retained level.
- Plan internal naming and external show copy with recovery using a copy outside the program. This candidate records no cues, loads no file, installs no profile, operates no console and changes no firmware.
ColorSource manual · 3.4.0 Rev A 2026-04 · selected pages · existing original
Frequently asked questions
Are twenty faders twenty DMX slots?
No. The data sheet identifies channel/playback faders; a control channel may represent a fixture with multiple parameters. Check the personality DMX footprint separately.
Where should a manual-working, recorded-dark comparison start?
Use the same fixture and patch while identifying the recorded section and its master. Preserve the file; that symptom does not justify cue deletion or console reset.
Does another playback always replace the previous color?
Manual 3.4.0 describes HTP intensity/color mixing between playbacks. Record simultaneous contributions and plan the intended transition without generalizing to position or other parameters.
Does zero playback master mean no position data?
The manual states an exception: playbacks containing position may continue supplying it. Verification must separate visible intensity and movement parameters.
Has Save As already created an external copy?
It saves another name inside the console. USB Export is separate; filename, copy existence and recovery need their own verification.
Follow the lighting control path
Official edition-specific documentation
ColorSource manual 3.4.0 Rev A, 2026-04: PDF 16/p. 7 masters; PDF 18/p. 9 patch; PDF 24/p. 15 manual control; PDF 36–37/pp. 27–28 recording/playbacks; PDF 65–66/pp. 56–57 settings; PDF 69–70/pp. 60–61 files. PDF 37 visually inspected. Rev H 2026-08 sheet: four pages read, p. 2 inspected. Existing originals SHA verified without new copies; remote manual/release-note access unavailable through the tool.