Model and documentation reference
Selected reference: standard Robe LEDBeam 350, shared FW/EP/FWEP manual version 2.6, dated December 1, 2022. Planning uses documented default Mode 3 with 24 channels; that establishes no actual fixture setting. Confirm the real variant, software and available profile. The manual diagram restricts Ethernet In/Out to the EP version.
Robe LEDBeam 350 · model identification
Event application
For an event in Argentina, separate the data feed to the stage from distribution to each fixture. A panel zone may need a stable look while a runway uses programmed changes: record each zone’s purpose, console owner and transition time. If the plan assumes direct Ethernet but the confirmed fixture is standard, review the final connection and required DMX output before finalizing cables, profiles and rehearsal time. No node or variant availability is assumed.
Robe LEDBeam 350/FW/EP/FWEP · manual EN 2.6 · 2022-12-01 · selected pages
Four decisions before finalizing the plan
| Item | Manual reference | Project confirmation |
|---|---|---|
| Standard LEDBeam 350 | Five-pin DMX In/Out in the diagram | Complete model and intended DMX path |
| EP variant | Ethernet In/Out marked EP version only | Actual ports, protocol, universe and path |
| DMX profile | Mode 1: 22; Mode 2: 16; Mode 3: 24 channels | Actual mode, console profile and nonoverlapping addresses |
| Color | RGBA/Amber text versus RGBW/White chart | Retain discrepancy; do not borrow another model’s recipe |
Robe LEDBeam 350/FW/EP/FWEP · manual EN 2.6 · 2022-12-01 · selected pages
Plan the final connection for the variant
For the standard reference, the documentary path runs from a console or specified node DMX output to fixture DMX In. Any network conversion requires identifying that node separately. EP Ethernet requires matching source/receiver protocol and universe; physical link alone establishes neither. The manual limits the EP Ethernet IN–OUT chain to eight fixtures: this connection limit guarantees no redundancy and defines no entire-system capacity. Mode 3 starting at 101 would occupy 101–124 as a calculation example, with no actual patch assigned.
Robe LEDBeam 350/FW/EP/FWEP · manual EN 2.6 · 2022-12-01 · selected pages
Keep the color discrepancy open until fixture and profile are identified
The manual C Mix M section refers to RGBA and Amber while its DMX chart identifies White and RGBW. Similarity to LEDBeam 150 resolves none of this, and Amber is not converted into White by assumption. Record complete model, known revision and intended profile; retain color attributes for documentary reconciliation and competent testing. Agree on scenes and references for the actual cameras. A color name or console setting establishes no uniformity, flicker-free result or automatic following.
Robe LEDBeam 350/FW/EP/FWEP · manual EN 2.6 · 2022-12-01 · selected pages
Prepare by zone, variant and profile
- Collect each fixture’s complete designation and document revision: standard, FW, EP or FWEP. Do not infer ports or diffusers from a generic family photo.
- Mark signal origin, any network section and final DMX or EP Ethernet connection per zone. Identify external nodes by their own model and documentation.
- Allocate space for the confirmed mode. Compare the documented 22, 16 or 24 channels with the console profile; 101–124 applies only to the 24-channel Mode 3 example.
- Record the RGBA/White discrepancy and panel, runway and camera scenes needing review. Do not compensate for uncertain identification with calibration or another fixture’s values.
- Agree on rehearsal/return owner, available window and how actual observations will be recorded. Connection, reception, movement and color remain pending until checked in the project.
Robe LEDBeam 350/FW/EP/FWEP · manual EN 2.6 · 2022-12-01 · selected pages
Frequently asked questions
Does every LEDBeam 350 accept Ethernet directly?
The manual marks Ethernet as EP only. Confirm full designation and actual ports; the standard reference plans five-pin DMX.
Do all three DMX modes use the same footprint?
No. The manual lists 22, 16 and 24 channels. Console and fixture must match modes before calculating the next address.
Is eight fixtures the maximum capacity of any system?
No. The documented limit applies to the EP Ethernet IN–OUT chain. It does not by itself define console, node, other-line or infrastructure limits.
Can Amber and White be treated as equivalents temporarily?
That equivalence is undocumented. Keep the text/chart conflict open and identify fixture/profile before defining attributes or values.
Does a correct console scene confirm the camera result?
No. Scene, camera and transition need representative review. This material prepares that review without establishing rehearsal, following or fixture availability.
Follow the lighting control path
Download the LEDBeam 350 variant, signal and profile worksheet
Official edition-specific documentation
Existing SHA-verified official English LEDBeam 350/FW/EP/FWEP manual 2.6, change dated December 1, 2022. Selective identification, connection, mode and chart consultation; PDF pages 5, 12, 19 and 36 visually inspected. Source record preserves extract positions and limits; no full 39-page read is claimed. Official model page text consulted. Official source linked; no PDF or local reader added.