info@eventosglobales.com.arWhatsApp · +54 9 11 5626-6200

← Back to guides and resources

Reference documentation · Video, LED and playback

NovaStar CVT4K-S and CVT4K-M: fibre and port groups

Plan the optical path between control and display by identifying the variant and both ends. Compare CVT4K-S V1.0.5 and CVT4K-M V1.0.4, separating link status, data transmission and the correct image in each group.

These guides help you prepare and check your production systems. Documented models are technical references; enquire about the equipment and services we can prepare for your project.

Preparing displays for conferences, stands and stages

Start with the content, display surfaces and who supplies each part of the system. A plan, label photos and the existing configuration help frame a video and display enquiry. Technical details help define the preparation, rehearsal and operation your project needs.

Identify the variant and signal path

Read the converter and optical module labels at both ends. Separate control ports from signal ports and confirm controller compatibility before changing connections.

Fiber, port groups and indicators

The NovaStar CVT4K optical link will not establish before connecting the LED screen. How do I check the variant and fiber?

Read the full converter designation and the optical module identification at both ends. An LC connector alone does not identify the required fiber or establish compatibility: distinguish CVT4K-S from CVT4K-M first.

The cited specifications cover CVT4K-S and CVT4K-M. S specifies dual-fiber OS1/OS2 single-mode, 9/125 µm and a 1310 nm module; M specifies dual-fiber OM3/OM4 multimode, 50/125 µm and an 850 nm module. If the label differs or the modules have been replaced, identify that combination before applying these values.

  1. Before touching connections, record the controller model and firmware, CVT4K variant, module references, fiber, ports and route. Check the controller documentation for support of that converter and those modules. Optical ports on both devices do not prove compatibility.
  2. Observe PWR and STAT. For the two documented variants, steady red PWR indicates normal power and flashing green STAT indicates normal device operation. If they do not show these states, check power and startup before blaming the fiber. Do not hot-plug PowerCON: page 4 prohibits it.
  3. Compare the fiber type, two strands and LC connectors with the identified variant. Note the specified fiber-selection limits: S, insertion loss ≤0.3 dB; M, ≤0.2 dB; both, return loss ≥45 dB. These are selection specifications, not measurements of the installed link.
  4. During a test window, replace only the fiber segment with a previously verified cable of the correct specification, keeping the same ports and modules. Do not look into fibers or optical ports. Observe the green indicator of the OPT port in use: steady means a normal optical connection according to the specification; it does not yet prove a correct picture on the screen.
  5. If the indicator changes with the test segment, record the difference and inspect the original cabling. If it does not, the far end, module and compatibility of the combination still need checking. Restore the recorded connection if there is no improvement, and keep the link out of the live signal path until an image test is complete.
On a NovaStar CVT4K-S or CVT4K-M, outputs 1–8 have a picture but 9–16 do not. What should I check before changing the LED map?

Check the OPT2 path first: both specifications assign it to signal ports 9–16. OPT1 corresponds to 1–8. Connecting only the OPT1 path does not check whether data reaches the second group.

OPT3 backs up OPT1, and OPT4 backs up OPT2. They are not two additional groups of eight outputs. The ETHERNET port in the CONTROL section connects a control computer; the type-B USB port is also for control and is not used to cascade converters.

  1. Record the diagram and save the current controller configuration using the tool for its model. Identify which controller output feeds each CVT4K OPT port; this guide does not establish matching port numbers on another device.
  2. Compare the CVT4K OPT1 and OPT2 indicators. Steady green means a normal optical connection. If OPT1 has that state and OPT2 does not, start with the second optical path and its fiber variant, without changing receiving cards or the screen map yet.
  3. Choose one affected port among 9–16 and one working port among 1–8. On signal ports, steady green indicates an Ethernet cable connection, flashing yellow indicates data transmission, and steady yellow indicates no data transmission. Record each color separately: a physical link does not mean data is arriving.
  4. With OPT2 normal, if the affected port has steady green and steady yellow, check whether the controller is sending data through that path. If green link indication is absent, test its Ethernet segment with a previously verified cable, keeping the same port number. If data is being transmitted but there is still no picture, continue to the receiving cards, cabinet wiring and documented configuration of that screen.
  5. Change one item at a time during the test and record its effect. Restore the previous connection if there is no improvement. Before taking the signal live, check both groups with a recognizable image and the intended map; indicators do not prove that content is reaching the correct cabinet.

Choose fiber after identifying the variant

This table summarizes page 3 of the cited specifications. Compare the values with the installed module labels and the route you plan to use.

VariantFiber and connectorDocumented module and distance
CVT4K-SOS1/OS2 single-mode, two fibers; 9/125 µm; LC1310 nm; 10 km
CVT4K-MOM3/OM4 multimode, two fibers; 50/125 µm; LC850 nm; 300 m
Download the blank fiber and port worksheet

Test before the event

Prepare a record for each end and port group. Note power, optical link, Ethernet link and data transmission states before changing a cable.

During the test, change one segment at a time and then check a recognizable image in both groups. The worksheet stays blank until actual observations are recorded.

This guide applies to CVT4K-S and CVT4K-M with the optical configuration described in their specifications. CVT4K without the suffix is insufficient to select fiber or modules.

The 10 km and 300 m figures are manufacturer-specified distances, not guarantees for a particular fiber route. Splices, adapters or different modules require checking their documentation and losses.

Use the models, firmware and documentation at both ends to configure redundancy and map the controller ports to the CVT4K ports.

Preparing the enquiry and test

Gather what is available: event purpose and city, cabinet plan, video source, models and versions. The date or equipment may still be undecided. Identify who retains the originals and authorises changes. Agree a test unit and window, acceptance criteria and recovery procedure before making changes.

Editable identification and test worksheet

Download blank TXT worksheet

Other guides for comparing signal paths

Each guide applies to its named model and edition. Check system compatibility before combining equipment or transferring a procedure.

Manuals and editions

Check the stated model, edition and language at the manufacturer’s source. Verify the document edition and installed software version separately.

Documentation consulted

Document adaptation: October 29, 2026. Check your system model and version before applying changes.

Let’s prepare your event system

Tell us what you want to show, hear or light and what your production already provides. Start with the idea and add models, dimensions and schedules later. Mention the model or guide in your message; the related service is selected in Contact.

Enquire about equipment and servicesView the related serviceEvent preparation guide