info@eventosglobales.com.arWhatsApp · +54 9 11 5626-6200

← Back to guides and resources

Reference documentation · Lighting

GigaCore 10t: plan event ports, groups and network links

Plan the control-to-stage network around actual devices, destinations and distances. Separate Ethernet transport from DMX generation and verify the variant before selecting fiber or PoE power.

These guides help you prepare and check your production systems. Documented models are technical references; enquire about the equipment and services we can prepare for your project.

Model and edition

This guide uses second-generation GigaCore 10t, product-code family LU 01 00079, and the nine-page Product specifications v1.0.2. The earlier GigaCore 10 and the 10t-IP have their own documentation. The 10t name alone does not identify fiber speed, optical connector or PoE provision.

Event application

For a conference with lighting control at front of house and nodes near the stage, draw the sender, switch and receivers. If audio or intercom shares the physical route, record each application and its group. Coordinate the connection with the venue network administrator before setup; an example topology is not a verified installation.

What to check in the product code and drawing

What to check in the product code and drawing
Documented resourceHow it differsRequired record
8 copper etherCON portsFour front and four rear; 10/100/1000 BASE-T ports.Connected device, negotiated speed, role and Group/VLAN.
Optional fiber connectionsThe range offers 1G/10G variants and connectors by product code; the sheet specifies fixed fiber speed.Full code, compatible speed and optics at both ends, fiber and distance.
Optional PoEPoE and non-PoE variants are separate entries in the ordering table.Confirmed variant, per-device requirement and total budget; etherCON alone does not establish PoE.
Groups/VLANs and inter-switch linksSegment and transport network applications; they are not DMX universe numbers.Sender and receiver group, links carrying that group and design responsibility.

Specifications v1.0.2 PDF pp.2–3 and5–7. Check the actual system before selecting accessories or powered loads.

Management access and signal reception are different checks

The switch transports Ethernet traffic; a physical DMX fixture needs an appropriate node or receiver. For multicast sACN, document group, transport and reception. The sheet includes IGMP and snooping but does not replace project-specific querier and topology design. An accessible management page does not demonstrate that a receiver gets the intended universe.

Specifications PDF pp.2,4,6–7. No traffic was captured and no settings were applied.

From the device list to a signal-path test

  1. Record full model, firmware, ports, destinations, distances and applications sharing the cable route. Separate management, lighting and other roles on the drawing.
  2. Draw each link and record the groups it must carry. Identify venue-network connection points and who may change them.
  3. Check the product code before preparing fiber or PoE. Verify the remote end too: both devices, connectors and medium define a link.
  4. Plan a test with identified sources and receivers and representative traffic. Record reception at each destination, rather than only link indicators or interface access.
  5. If redundant paths are required, define topology and compatible functions before cabling. The sheet describes RLinkX; do not form a loop by analogy or promise recovery time without a test.

Specifications PDF pp.2–7. This plan runs no software, network changes or physical tests.

Frequently asked questions

Are all ports 10 Gb/s?

No. The sheet distinguishes eight copper Gigabit ports from the 1G/10G fiber options. Confirm product code and speed at both ends.

Is a Group a DMX universe?

No. A group segments traffic through VLANs. For the lighting path, sender, node and receiver must agree on protocol and universe.

Can the unit power any node?

The model name alone cannot establish that. Confirm the PoE variant, standard, receiver demand and system budget. This guide does not calculate or approve loads.

How can we start a proposal?

Tell us the venue, control position, destinations and approximate distances. We can evaluate a dedicated network or documented integration with an existing one, together with agreed signal distribution and operation.

Connect the two parts of the signal path

LumiNode 4: plan sources, engines and DMX outputs

Worksheet for planning the map and test

Exact documentation

English original; the ES/PT guides are our own adaptations.

Documentation consulted

Document review: October 31, 2026. Cited pages read; no system test or installed-firmware identification.

Luminex · GigaCore 10t: plan event ports, groups and network links

Plan distribution for your event

Tell us how control and stage are distributed and what network the venue provides. We can evaluate equipment and services for cabling, data distribution and coordinated operation. Mention GigaCore 10t and the unit code if known; technical documentation does not establish commercial availability.

Enquire about equipment and servicesView the related serviceEvent preparation guide