Model and documentation reference
The manual table separates Micro F-1, a transceiver selectable as TX or RX, from the receive-only Micro R-512. Selectable roles do not establish simultaneous TX/RX repeater operation. The Micro section excludes Triple Band and Double-Up; BlackBox, WhiteBox and ProBox features do not transfer merely because they share the G5 manual. Identify actual unit, version and radio mode; no Eventos Globales inventory is confirmed.
Wireless Solution W-DMX G5 · January 2019 · 2nd edition · Micro sections · EN
Event application
For a stand, institutional event or stage in Argentina, record console, proposed universe and patch, DMX output, wireless segment and destination devices. Record each supplier’s scope, power, cabling and owners. Avoiding a DMX cable crossing still leaves power and equipment placement to resolve; radio alone establishes neither clear access, coverage nor installation approval.
Wireless Solution W-DMX G5 · January 2019 · 2nd edition · Micro sections · EN
Four records before proposing the link
| Item | Documented fact | Actual-system record |
|---|---|---|
| Model / role | Micro F-1 can be TX or RX; Micro R-512 is RX only | Model/role at each end; no repeater inference |
| DMX connection | Micro section: 5-pin XLR, male for F-1 and female for R-512 | Actual connectors, cables and signal direction |
| Power | Micro USB 5 V or four AAA; USB does not recharge batteries | Identified supply/batteries; power separate from DMX data |
| Mode / state | Micro excludes Triple Band/Double-Up; LINK and DATA are distinct | Compatible mode and pending observations; patch/response to verify |
Wireless Solution W-DMX G5 · January 2019 · 2nd edition · Micro sections · EN
From patch to fixture: radio and data are separate stages
Trace console, DMX output/universe, transmitter, radio link, receiver and destination cable in the matrix. On a receiver, LINK describes transmitter association; DATA reports data presence under the manual. Neither validates the universe, start address, fixture personality or response by itself: project records must match and be checked in a later test. Micro USB supplies power, not USB DMX input from a console. The generic Micro illustration replaces no identification of an actual F-1 connector.
Wireless Solution W-DMX G5 · January 2019 · 2nd edition · Micro sections · EN
Plan association and placement without touching operating equipment
The manual warns that linking can include every available, powered receiver compatible with the transmitter radio mode. It distinguishes individual/group unlinking and requires receiver relinking after CTRL changes. List intended and unrelated units before the test window; these changes are not proposed as show-time troubleshooting. For Micro, the manufacturer recommends keeping units visible and facing their displays toward each other. Obstructions and actual conditions need rehearsal, without distance or interference-immunity promises.
Wireless Solution W-DMX G5 · January 2019 · 2nd edition · Micro sections · EN
Document the proposed link
- Identify Micro F-1 G5 and every other endpoint model. Record version and TX/RX role still to verify; copy no R-512 or BlackBox capability.
- Draw the full signal path and record the lighting owner’s proposed universe, patch, start address and personality. List actual cables/connectors per segment.
- List intended pairing units and those belonging to other systems. Assign approval for a test window; perform no pairing, unlinking or CTRL change to fill this sheet.
- Document Micro USB 5 V or four-AAA power, supply and replacement plan. Separate power from data and retain actual battery runtime as pending.
- Propose facing-display positions and record obstructions. Plan per-segment checks with owners, LINK/DATA observations and destination response; perform no power-up, wiring, setup, software installation or firmware update.
Wireless Solution W-DMX G5 · January 2019 · 2nd edition · Micro sections · EN
Frequently asked questions
Do Micro F-1 and Micro R-512 do the same job?
No. The table shows TX/RX roles for F-1 and receiver-only operation for R-512. Identify actual unit before assigning role or connector.
Can G5 add Triple Band or Double-Up to Micro?
The Micro section and mode note exclude those functions for the series. The G5 name transfers no other model’s capabilities.
Does Micro USB carry computer DMX and charge AAA batteries?
The Micro section defines it as power supply only. It does not recharge AAA cells, including rechargeable ones, or establish a USB DMX interface.
Does a lit LINK prove correct patch?
No. Radio association, data presence and DMX response require separate checks. Project universe, address and personality must also match.
Does the RDM table mark prove it is active in the system?
No. Capability and activation differ; the manual states RDM is disabled by default and identifies R-512 limitations. Actual state/path remain pending without installing configurators or changing settings here.
Complete the lighting brief
Identified official documents
Official W-DMX G5 manual, edition 2, January 2019, existing original SHA verified. Only PDF positions 1, 3, 4, 7–14, 20, 26 and 27 were read; 7, 9, 11, 20 and 27 were visually inspected. The complete 28-page manual is not claimed read. Micro restrictions govern; BlackBox examples are not F-1 instructions. Official original hosted by LumenRadio; no new PDF copy, imported product photo or physical test.