Model and documentation reference
Selected documentary reference: ME-3750 part 319336, with adjustable height of 36–56 inches in the manual table. The same document lists 319348 for 48–78 inches. Keep these references distinct: the actual ME-3750, part number and decks remain to be identified. Neither that table nor the system name establishes Eventos Globales inventory or availability in Argentina.
StageRight ME-3750 · manual EN · filename20161209 · PDF metadata2009 · printed revision unconfirmed
Event application
For a conference, awards event or performance, the finished platform may need to share space with service access and scenery changes. Record storage, proposed use position and route, with doors, turns, gradients and receiving floor to review at the actual venue. List intended stage items separately and identify a work window clear of the audience. Any proposal depends on assembly, site conditions and installation-owner review.
StageRight ME-3750 · manual EN · filename20161209 · PDF metadata2009 · printed revision unconfirmed
Four records that separate movement from use
| Item | Documented fact | Pending review |
|---|---|---|
| Selected reference | 319336: 36–56 inches; 319348: 48–78 inches | Actual support code and height; do not interchange references |
| Decks and locators | The document describes positioning and locator layouts | Model, quantity, orientation and correspondence with the complete plan |
| Casters / travel | The manual covers movement with decks positioned | Route and actual assembly condition; no occupied-transport authorization |
| Feet / jam nuts | Stationary support uses screw feet and jam nuts, distinct from casters | Competent review of final support, receiving floor and intended-use handover |
StageRight ME-3750 · manual EN · filename20161209 · PDF metadata2009 · printed revision unconfirmed
From proposed route to stationary support
The manual distinguishes movement with decks positioned from stationary support on screw feet and jam nuts. Record those states separately: the assembly proposed for movement, its route and the person responsible for checking the final condition. Movement with decks establishes no permission to transport people, equipment or additional loads. This guide organizes information; it replaces neither complete instructions nor a caster, pin or adjustment procedure.
StageRight ME-3750 · manual EN · filename20161209 · PDF metadata2009 · printed revision unconfirmed
Complete layout, interfaces and staffing
The manufacturer requires at least two people for complete setup. That minimum promises no sufficient staffing for every venue, route or schedule. Bridging and locator drawings describe particular arrangements; they do not authorize removing supports from arbitrary layouts. Relate each deck to its supports and interfaces, retaining unidentified components as pending. Product weight in a specification table must not become stage load capacity.
StageRight ME-3750 · manual EN · filename20161209 · PDF metadata2009 · printed revision unconfirmed
Document the proposed position change
- Identify model and part number. Use 319336 and 36–56 inches only as the selected documentary reference; match any different actual unit to its own records before confirming dimensions.
- List decks, supports, locators and proposed accessories. Draw the complete assembly and mark unresolved parts or interfaces; appearance establishes no compatibility.
- Separate storage, route and use position on the plan. Record actual measurements still needed, obstructions, receiving floor and access for responsible venue review.
- Define a work window and owners of staffing, assembly and stationary-condition review. Retain the manual minimum of two people without treating it as a complete staffing calculation.
- Record pending inspection, rehearsal and handover. Filling this sheet requires no assembly, movement, caster operation, pin release, foot or jam-nut adjustment, or load testing.
StageRight ME-3750 · manual EN · filename20161209 · PDF metadata2009 · printed revision unconfirmed
Frequently asked questions
Are 319336 and 319348 the same reference?
The manual assigns different ranges: 36–56 and 48–78 inches respectively. This guide selects 319336; identify the actual unit before applying either record.
Does movement with decks mean people can ride on them?
That authorization is not established. The document covers decks positioned during movement; it is not extended here to people, equipment or added loads.
Do casters also describe final support during use?
These are separate documented states. The manual distinguishes casters for movement from screw feet and jam nuts for stationary support. Actual condition and receiving floor require review.
Does two people guarantee sufficient staffing?
The manual states at least two for complete setup. Event and venue requirements need separate assessment; a minimum is no staffing calculation for every repositioning.
Do bridging drawings permit support removal?
No general authorization is inferred. Review the complete plan, corresponding decks, locators and supports, instructions and intended use.
Continue the layout and brief
Identified official documents
Official English ME-3750 manual, an existing original verified by SHA. Its filename ends in 20161209 while PDF metadata dates to 2009; no printed 2016 revision is claimed. All 12 pages of text were read; PDF positions 5, 6, 8, 9 and 10 were visually inspected. Other illustrations, equipment and venue were not inspected. The link points to the official original; no copy was added to the local reader.