info@eventosglobales.com.arWhatsApp · +54 9 11 5626-6200

← Back to guides and resources

Reference documentation · Event planning

StageRight ME-3750: separate travel, stationary support and stage handover

A program change may require a stage to be moved away and repositioned between sessions. For that inquiry, separate storage position, proposed travel route and final use condition. ME-3750 identifies a rolling support system; saying a stage has casters is insufficient. Decks, locators and supports need to match the documentation and complete event layout.

These guides help you prepare and check your production systems. Documented models are technical references; enquire about the equipment and services we can prepare for your project.

Model and documentation reference

Selected documentary reference: ME-3750 part 319336, with adjustable height of 36–56 inches in the manual table. The same document lists 319348 for 48–78 inches. Keep these references distinct: the actual ME-3750, part number and decks remain to be identified. Neither that table nor the system name establishes Eventos Globales inventory or availability in Argentina.

StageRight ME-3750 · manual EN · filename20161209 · PDF metadata2009 · printed revision unconfirmed

Event application

For a conference, awards event or performance, the finished platform may need to share space with service access and scenery changes. Record storage, proposed use position and route, with doors, turns, gradients and receiving floor to review at the actual venue. List intended stage items separately and identify a work window clear of the audience. Any proposal depends on assembly, site conditions and installation-owner review.

StageRight ME-3750 · manual EN · filename20161209 · PDF metadata2009 · printed revision unconfirmed

Four records that separate movement from use

Four records that separate movement from use
ItemDocumented factPending review
Selected reference319336: 36–56 inches; 319348: 48–78 inchesActual support code and height; do not interchange references
Decks and locatorsThe document describes positioning and locator layoutsModel, quantity, orientation and correspondence with the complete plan
Casters / travelThe manual covers movement with decks positionedRoute and actual assembly condition; no occupied-transport authorization
Feet / jam nutsStationary support uses screw feet and jam nuts, distinct from castersCompetent review of final support, receiving floor and intended-use handover

StageRight ME-3750 · manual EN · filename20161209 · PDF metadata2009 · printed revision unconfirmed

From proposed route to stationary support

The manual distinguishes movement with decks positioned from stationary support on screw feet and jam nuts. Record those states separately: the assembly proposed for movement, its route and the person responsible for checking the final condition. Movement with decks establishes no permission to transport people, equipment or additional loads. This guide organizes information; it replaces neither complete instructions nor a caster, pin or adjustment procedure.

StageRight ME-3750 · manual EN · filename20161209 · PDF metadata2009 · printed revision unconfirmed

Complete layout, interfaces and staffing

The manufacturer requires at least two people for complete setup. That minimum promises no sufficient staffing for every venue, route or schedule. Bridging and locator drawings describe particular arrangements; they do not authorize removing supports from arbitrary layouts. Relate each deck to its supports and interfaces, retaining unidentified components as pending. Product weight in a specification table must not become stage load capacity.

StageRight ME-3750 · manual EN · filename20161209 · PDF metadata2009 · printed revision unconfirmed

Document the proposed position change

  1. Identify model and part number. Use 319336 and 36–56 inches only as the selected documentary reference; match any different actual unit to its own records before confirming dimensions.
  2. List decks, supports, locators and proposed accessories. Draw the complete assembly and mark unresolved parts or interfaces; appearance establishes no compatibility.
  3. Separate storage, route and use position on the plan. Record actual measurements still needed, obstructions, receiving floor and access for responsible venue review.
  4. Define a work window and owners of staffing, assembly and stationary-condition review. Retain the manual minimum of two people without treating it as a complete staffing calculation.
  5. Record pending inspection, rehearsal and handover. Filling this sheet requires no assembly, movement, caster operation, pin release, foot or jam-nut adjustment, or load testing.

StageRight ME-3750 · manual EN · filename20161209 · PDF metadata2009 · printed revision unconfirmed

Frequently asked questions

Are 319336 and 319348 the same reference?

The manual assigns different ranges: 36–56 and 48–78 inches respectively. This guide selects 319336; identify the actual unit before applying either record.

Does movement with decks mean people can ride on them?

That authorization is not established. The document covers decks positioned during movement; it is not extended here to people, equipment or added loads.

Do casters also describe final support during use?

These are separate documented states. The manual distinguishes casters for movement from screw feet and jam nuts for stationary support. Actual condition and receiving floor require review.

Does two people guarantee sufficient staffing?

The manual states at least two for complete setup. Event and venue requirements need separate assessment; a minimum is no staffing calculation for every repositioning.

Do bridging drawings permit support removal?

No general authorization is inferred. Review the complete plan, corresponding decks, locators and supports, instructions and intended use.

Continue the layout and brief

Download the ME-3750 route and stationary-support sheet

Identified official documents

Official English ME-3750 manual, an existing original verified by SHA. Its filename ends in 20161209 while PDF metadata dates to 2009; no printed 2016 revision is claimed. All 12 pages of text were read; PDF positions 5, 6, 8, 9 and 10 were visually inspected. Other illustrations, equipment and venue were not inspected. The link points to the official original; no copy was added to the local reader.

Plan the stage for your event

For a mobile-stage inquiry in Argentina, share city, venue, program, layout, required surface and height, storage position, route and changeover windows. For an identified ME-3750, include part number, decks and documents. The inquiry scopes preparation for review; components, availability, staffing and scope require confirmation.

Enquire about equipment and servicesView the related serviceEvent preparation guide