Model and documentation reference
Documented reference: ARRI Orbiter Blue/Silver body L1.0033520 with Projection 35° optic L2.0033550 using QLM. This combination illustrates a shutter-cut task and establishes no Argentine availability. The official page distinguishes four manual shutter blades from motorized focus. A 35° angle identifies neither a zoom range nor installed LiOS.
ARRI Projection 25° / 35° · L2.0033549 / L2.0033550
Event application
For a presentation, play or recording in Argentina, draw the presenter position, screen boundary, people paths and cameras. Identify the surface that needs light and the area to keep clear. Record distances and framing before selecting optics: a wider source may spill into unwanted areas, while a narrower one may need another position. Include scene changes and operator access to focus in the plan.
ARRI Orbiter · brochure L04142 / 80.0033512 · PDF 4,16 · ARRI Projection 25° / 35° · L2.0033549 / L2.0033550
Select optics by task
| Orbiter reference | Documented function | Planning consequence |
|---|---|---|
| Projection 35° · L2.0033550 | Four manual blades and motorized focus | Plan access for shutter cuts; focus and shutters differ |
| Projection 25° · L2.0033549 | A separate projection optic with a different angle | Reassess position and coverage before substitution |
| Fresnel 15–65° | Motorized zoom range | Do not assign that zoom to Projection 35° |
| Open Face 15°, 30° or 60° | Directional beam from the selected optic | A similar body does not establish projection shutters |
ARRI Orbiter · brochure L04142 / 80.0033512 · PDF 4,16 · ARRI Projection 25° / 35° · L2.0033549 / L2.0033550
Separate signal, power and personality
The brochure identifies five-pin DMX input/through, Ethernet input/through and Art-Net/sACN control options. The three-pin battery connection is a different interface; connector appearance is no reason to treat it as DMX input. Prepare a row linking console, intended protocol, universe, start address and exact Orbiter personality. No channel map or count is assigned here: the permitted operating manual and actual unit version/mode are missing. Two Ethernet connections also establish no redundancy.
ARRI Orbiter · brochure L04142 / 80.0033512 · PDF 4,16 · ARRI Projection 25° / 35° · L2.0033549 / L2.0033550
Plan a lighting comparison without claiming a rehearsal
Keep brochure L04142 and the dedicated Projection page as references. The page links optic recognition to LiOS 2, which does not establish an actual unit version. Request the body, optic and LiOS record before finalizing control. For a later test, agree on camera framing/exposure, a screen scene, low-level output and a transition. Do not copy a SkyPanel personality or promise that matching console values will match different light sources.
ARRI Projection 25° / 35° · L2.0033549 / L2.0033550 · ARRI Orbiter · official FAQ · model-specific scope
Prepare the rehearsal worksheet
- Record body L1.0033520, optic L2.0033550 and the actual intended components. Leave serial, LiOS, support and accessories pending without evidence; a documented reference is no inventory.
- Mark useful area, surfaces to protect, distances, camera positions and people paths. Separate manual shutter adjustment from focus control. This guide performs no mounting.
- Prepare the documentary console–protocol–universe–address–personality–fixture route. Leave channel count open until permitted documentation and actual mode are available.
- Define comparable observations: presenter with screen, edge cuts and scene transition. Record camera configuration and each observation goal without calling the test completed.
- Assign a documentation, mounting and rehearsal owner/window. Preserve initial state and open decisions; this package changes no network, personality, LiOS or firmware.
ARRI Orbiter · brochure L04142 / 80.0033512 · PDF 4,16 · ARRI Projection 25° / 35° · L2.0033549 / L2.0033550
Frequently asked questions
Does remote focus also move the shutters?
The Projection reference describes motorized focus and four manual blades. Plan access to shutter cuts separately from focus control.
Does Projection 35° have 15–65° zoom?
That range belongs to Orbiter Fresnel. Projection identifies separate 25° and 35° optics; do not transfer a range between accessories.
Which DMX channels should I patch?
No permitted channel table is included here. Identify exact version/personality and obtain authorized documentation before defining address and universe occupancy.
Can I use a SkyPanel personality because both are ARRI?
Do not assume so. Manufacturer identity establishes no common personality; record each source model/mode and verify its exact documentation.
Does this sheet prove a good presenter and screen camera image?
No. The result depends on the system, positions, levels and camera. The sheet prepares rehearsal observations; it approves neither image nor mounting.
Follow the lighting control path
Official edition-specific documentation
Orbiter brochure L04142 / 80.0033512: existing 19-position PDF, positions 1–10 and 16–19 read; 4 and 16 visually inspected. Its imprint says published February 2025 and retains a separate 02/2024 mark. Official Projection, Optics and FAQ page text consulted. Operating manual L03917 is held and excluded, neither read nor materialized for this candidate. The brochure links to its official origin without a new copy or tested local reader.